Abstract

This paper presents the results of experimental and theoretical study on the behavior of reinforced concrete-filled glass fiber reinforced polymer (GFRP) tubes (RCFFTs) under eccentric compression loading. A total of six RCFFT specimens were tested, the effects of the following parameters were examined: GFRP tube thickness (4.5 and 6.0 mm), longitudinal reinforcement, inserted I-shaped steel, and eccentricity (20 and 40 mm). The results of this investigation indicate that the ultimate load capacity and ductility of the RCFFT specimens are improved in terms of increasing the thickness of the GFRP tube under eccentric load. However, increasing the eccentricity significantly decreases the load capacity of RCFFT specimens. The internal steel bar could enhance the rigidity and loading capacity of RCFFT specimens. Furthermore, ultimate load capacity and ductility of the specimen are increased significantly by inserting shaped steel into concrete filled GFRP tube, Also, the simplified design equations are proposed to predict the ultimate load capacities of RCFFT specimens.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.