Abstract

The purpose of this investigation is to clarify the behavior of exit keyhole diameter during switch off (cutting arc) period in case of Plasma keyhole arc welding (PKAW). During switch off period, the keyhole and weld pool are visualized from backside via a high speed video camera (HSVC). The result showed that keyhole diameter on the backside is unstable. The keyhole size is much changed in X-axis. Firstly, it is increased and then it is decreased to a stationary value at t = 0.05 s after cutting arc. Meanwhile, the size in Y-axis is not changed approximately from t = 0.01 s after cutting arc. The results can be considered to control this process more efficiency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.