Abstract

The energy loss due to the excitation of parasitic modes in the SPEAR II rf cavities and vacuum chamber components has been measured by observing the shift in synchronous phase angle as a function of circulating beam current and accelerating cavity voltage. The resulting parasitic mode loss resistance is 5 MΩ at a bunch length of 6.5 cm. The loss resistance varies with bunch length σz approximately as exp(-0.3 σz). If the measured result is compared with reasonable theoretical predictions, we infer that the major portion of the parasitic loss takes place in ring vacuum components rather than in the rf cavities.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.