Abstract

Beam orbit of the PF ring is adjusted to deliver the photon beams on the proper axes of all experimental beam lines. During the user time, the beam orbit is maintained at the reference orbit by an orbit feedback system. In the vertical direction, the feedback was performed at a high repetition rate as 10 ms. In order to improve the stability and reliability of the beam position measurement, we have continued the beam based alignment of BPM. The remnant errors in the BPM offsets were estimated at all BPMs. A systematic error was found out at a specific part of the ring. We could fix a BPM that had an offset drift depending on the beam current. The amount of the drift was determined by the beam-based measurement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.