Objective Many methods are used to detect vertical root fractures, but most are not adequate for identification of incomplete fractures or cracks. The purpose of this study was to evaluate the effects of three detergents on detection of vertical root fractures by DIAGNOdent ® with methylene blue (MB) solution. Methods Vertical incomplete fractures were artificially created on the roots of extracted human teeth, the DIAGNOdent ® values ( D values) recorded in the presence or absence of MB solution, and the effects of detergents on D values examined. The effects of 20% ethanol on enhancing detergent action were also investigated. Statistical analysis was performed using the Mann–Whitney U-test; a value of p < 0.01 was considered significant. Results D values increased significantly when MB solution was used with 0.1% or 1.0% polyoxyethylene (10) octylphenyl ether compared to MB solution only. Conclusion These findings suggest that 0.1% or 1.0% polyoxyethylene (10) octylphenyl ether could be used as an enhancer for detection of vertical root fractures by DIAGNOdent ® using MB solution.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.