Abstract

A highly selective and sensitive poly(vinyl chloride) membrane electrode, using 4-4′-Methylenediantipyrine as an ionophore, has been prepared and examined as a Ba2+-selective electrode. The influence of the anion excluder (sodium tetraphenyl borate, NaTPB) and the effect of the plasticizers dibutyl phthalate (DBP), nitrobenzene (NB), and benzyl acetate (BA) were studied. The best performance was obtained with the sensor having a membrane composition (w/w) of (MAP, 2.0%), (PVC, 30%), (NB, 66%), (NaTPB, 2.0%) with a wide working concentration range of 1.0 × 10−6 to 1.0 × 10−2 M between the pH values of 3.4 and 10.6. Furthermore, a Nernstian slope of 29.7±0.3 mV/decade of activity was demonstrated with a response time of 15 s. The sensor could be used over a period of 2 months with no potential divergence, revealing a good selectivity for a broad variety of cations including alkali, alkaline earth, heavy and transition metals. Regarding the practical applicability of this sensing device, it was successfully applied for the Ba2+ ions detection in a lithophone pigment and as an indicator electrode in the potentiometric titration of the under study cations.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.