Abstract

IntroductionThe higher frequency of infections in diabetic patients is caused by a hyperglycemic environment, which promotes immune dysfunction. People with diabetes are more prone to skin infections.A continuous glucose monitoring (CGM) system provides information on changes in blood glucose (BG) levels throughout the day. Its use facilitates optimal therapeutic decisions for a diabetic patient. One of the factors limiting the use of CGM is inflammation at the insertion site.Aim of the studyThe aim of the study was the microbiological identification of the bacterial strains which are found on CGM sensor electrodes.Material and methodsWe performed microbiological tests on patients′ CGM Enlite Medtronic electrodes, which were removed after 6 days of usage according to the manufacturer′s instructions. 31 sensors were examined from 31 children (14 girls) aged from 0.5 to 14.6 years. The microbiological analysis was routinely performed at the Department of Children’s Diabetology Medical University of Silesia in Katowice, Poland.Results12 (39%) of the electrodes were colonized. In 11 (92%) cases the electrodes were colonized by one bacteria strain. 7 times methicillin-sensitive coagulase negative staphylococcus (MSCNS) was detected. We also found one case of Klebsiella pneumoniae, Ochrobactrum tritici, Bacillus sonorensis and methicillin-resistant coagulase-negative Staphylococci (MRCNS) colonization. One electrode was colonized by the mixed flora Enterococcus faecalis, methicillin-susceptible coagulase-negative Staphylococci (MSCNS), Pseudomonas stutzeri, methicillin-susceptible Staphylococcus aureus (MSSA). The median HbA1c in the group with colonization of electrodes was 6, 85% (6, 3–7, 6%) versus 6, 3% (5, 8–7, 5%) in the group without colonization. The median BMI in the group with colonization of the electrodes was 17.10 kg/m2 (16.28–18.62 kg/m2) versus 15.98 kg/m2 (15.14–17.96 kg/m2) in the group without colonization. Statistically, significantly more frequently electrodes are colonized in older children (median age in the group with colonization of electrodes 11.43 years (6.52–12.27 years), without colonization 8.42 years. (3.098–9.375 years); (p = 0.033).ConclusionsIt seems that older children are more likely to have their sensor electrode colonized by bacterial strains.

Highlights

  • The higher frequency of infections in diabetic patients is caused by a hyperglycemic environment, which promotes immune dysfunction

  • The aim of the study was to identify the bacterial strains that colonize the sensor electrodes of a Continuous glucose monitoring (CGM) system in children with diabetes

  • Single sensors were colonized by the bacterium of Klebsiella pneumoniae, Ochrobactrum tritici, Bacillus sonorensis and methicillin-resistant coagulase-negative staphylococci (MRCNS) colonization

Read more

Summary

Introduction

The higher frequency of infections in diabetic patients is caused by a hyperglycemic environment, which promotes immune dysfunction. Aim of the study The aim of the study was the microbiological identification of the bacterial strains which are found on CGM sensor electrodes. Material and methods We performed microbiological tests on patients′ CGM Enlite Medtronic electrodes, which were removed after 6 days of usage according to the manufacturer′s instructions. One electrode was colonized by the mixed flora Enterococcus faecalis, methicillin-susceptible coagulase-negative Staphylococci (MSCNS), Pseudomonas stutzeri, methicillin-susceptible Staphylococcus aureus (MSSA). Conclusions It seems that older children are more likely to have their sensor electrode colonized by bacterial strains. Diabetes is a group of metabolic diseases. They are characterized by chronic hyperglycaemia as the effect of insufficient insulin secretion, its disturbed action or both. Chronic complications of diabetes affect many organs. It is worth noting that the treatment of diabetes complications costs more than managing the disease itself [2]

Objectives
Methods
Results

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.