Abstract

Detection of water leaks in buried distribution pipes using acoustic methods is common practice in many countries. Correlation techniques are widely used in leak detection, but for these to be effective, the propagation wave speeds and wave attenuation must be known. Relatively predictable for metal pipes, these are largely unknown for the newer plastic pipes, being highly dependent on the pipe wall properties and the surrounding medium. In a previous paper a theoretical model of a buried fluid-filled pipe to predict both wavespeed and attenuation was presented; the aim of the work in this paper is to validate this model experimentally. Wavenumber measurements, encompassing both wavespeed and wave attenuation are made on a water-filled pipe in vacuo and on a buried water-filled pipe. In general, the measurements show good agreement with the theoretical predictions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.