Abstract

We recently needed to perform awake tracheal intubation (ATI) for a patient undergoing urgent maxillofacial surgery at our secondary hospital. During the coronavirus disease 2019 (COVID-19) pandemic all maxillofacial surgery patients are treated as suspected COVID-19 and ATI is widely regarded as high-risk for aerosol generation. We sought early multidisciplinary input and were informed by Ahmad et al.’s recent case report [1]. Our operating theatres have positive-pressure airflow. Negative-pressure rooms are available elsewhere in the hospital but we felt managing a difficult airway in an unfamiliar environment posed significant risk. Our available personal protective equipment comprised a disposable gown; N95 mask; goggles; full-face shield; and double gloves. We administered glycopyrrolate intravenously and used a topicalisation process designed to minimise aerosol generation: Pacey’s paste to the posterior tongue [2]; lidocaine 10% sprays to the oropharynx; lidocaine 4% via a mucosal atomiser device; and internal superior laryngeal nerve blocks using lidocaine 4%-soaked gauze and Jackson laryngeal forceps [3]. Following Difficult Airway Society guidelines [4], the total dose of lidocaine administered was < 9 mg.kg-1 (lean body weight) and a second anaesthetist administered remifentanil for conscious sedation by target-controlled infusion at 2 ng.ml−1. Oxygen 4 l.min−1 was given via Hudson mask with end-tidal carbon dioxide monitoring and a cut-out permitting oral access. Excellent topicalisation was achieved. First-pass orotracheal intubation was performed without complication using a disposable Ambu® aScope™ 4 Broncho size Regular (Ambu A/S, Ballerup, Denmark). A Shiley™ Lo-Contour flexible reinforced endotracheal tube of size 7.0 mm (Covidien Ireland Limited, Tullamore, Ireland) was used and the tracheal tube cuff was gently inflated before the induction of anaesthesia. We describe an effective aerosol-minimising approach to ATI. This process varied from our usual practise which typically includes high-flow nasal oxygen, the EZ-100m™ disposable atomiser (Alcove Medical inc., Houston, TX, USA) nasotracheal intubation and cuff inflation after induction of anaesthesia – these were avoided due COVID-19 aerosolisation concerns. Published with the written consent of the patient. No external funding or competing interests declared.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.