Abstract

The present article deals with a new procedure for determination of the herbicide flumetsulam. The fluorimetric procedure is performed on the basis of photo-increased fluorimetric emission of the pesticide solution and by means of a multicommutation continuous-flow assembly. The alkaline solution containing the analyte is irradiated online and then directly forced through the fluorimeter flow cell. The analysis of different samples is completely automated, as the analyte separation was performed online by including a separation cartridge in the manifold. When dealing with solid samples (such as soil samples), the automation was completed by adding to the manifold the corresponding device for the aqueous extraction of the analyte from the sample suspension.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.