Abstract

Assistant ProfessorDepartment of Anesthesia,Harvard Medical School and Children's HospitalBoston, Massachusettscasta@a1.tch.harvard.eduTo the Editor:—Inadvertent placement of an epidural catheter in the presacral area via the caudal route is described in a full-term infant who underwent repair of tracheoesophageal fistula.A 3.1-kg full-term boy infant with a prenatal diagnosis of tracheoesophageal fistula with esophageal atresia and left pulmonary agenesis presented at birth with respiratory distress. Routine monitors were placed in the operating room, and after preoxygenation an awake tracheal intubation was performed. Anesthesia was maintained with isoflurane, oxygen, and air with the infant breathing spontaneously. Chest and abdominal radiograms showed no vertebral anomalies. An epidural catheter was inserted in the caudal space using a sterile technique to facilitate perioperative pain management and early tracheal extubation. An 18-gauge angiocatheter was placed in the caudal space and a 20-gauge polyamide epidural catheter was advanced into the epidural space via the angiocatheter. No cerebrospinal fluid or blood was noted. The catheter was advanced with ease to the anticipated length for mid thoracic placement. No tachycardia, dysrhythmia, or increase in blood pressure was recorded after a test dose of 0.3 ml lidocaine, 1.5%, with epinephrine (1:200,000). An open gastrostomy was then performed. A loading dose of 1.5 ml bupivacaine solution, 0.125%, was given via the epidural catheter. This was followed by a continuous infusion of 0.05% bupivacaine and fentanyl (1 μg/ml) at 1 ml/h. The end-tidal concentration of isoflurane was kept constant during the gastrostomy, and no changes in the patient's blood pressure and heart rate were noted. Routine epidurography with 0.5 ml contrast (iohexol, 180 mg/ml) showed the catheter coiled in the presacral space (fig. 1).The epidural infusion was discontinued.The patient was then positioned for a right posterolateral thoracotomy. The fistula was ligated and divided, and the esophageal anastomosis was performed without complication. The caudally placed catheter was removed and replaced at the end of surgery. During a sterile technique, an 18-gauge Crawford epidural needle was placed in the caudal space. No blood or cerebrospinal fluid was noted. A 20-gauge polyamide epidural catheter was easily advanced to a premeasured distance from the caudal space to the mid thoracic area. An epidurogram (0.5 ml iohexol, 180 mg/ml) confirmed the tip of the catheter at the mid thoracic level and absorption of the contrast from the presacral space (fig. 2).No tachycardia, dysrhythmia, or increase in blood pressure was seen after a test dose of 0.3 ml lidocaine, 1.5%, with epinephrine (1:200,000). The epidural catheter was infused with 0.05% bupivacaine and fentanyl (1 μg/ml) at 1 ml/h. The patient was breathing spontaneously and underwent ventilation at arrival to the intensive care unit. Fentanyl was removed from the epidural infusion and the analgesia was adequate. The patient was weaned from the ventilator and the trachea was extubated in the next 24 h. The epidural catheter was removed on the fourth postoperative day.Thoracic epidural anesthesia via the caudal approach has been reported with success in neonates and infants. Gunter and Eng 1were able to place a thoracic epidural using the caudal approach in 19 of 20 children. However, Blanco et al. 2reported a lower success rate when attempting thoracic epidural placement from the lumbar region in children. They also found that the ease of advancement of the epidural catheter does not necessarily predict the desired catheter position.Epidural needles and angiocatheters have been used for entering the caudal space in infants. 3,4In our patient, the 18-gauge angiocatheter probably entered the presacral space via the lower portion of the sacrum, and the epidural catheter was easily threaded into the presacral space. This complication was not seen when the Crawford needle was used. Confirmation of the position of the catheter before starting an infusion is therefore recommended because the ease in advancement of the catheter may be misleading.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.