Abstract
SUMMARY Programmed electrical stimulation techniques were used to evaluate the effects of halothane and isoflurane on induction of atrial fibrillation in anesthetized dogs. Experiments were performed in 16 dogs anesthetized with α-chloralose. Critically timed premature stimuli were applied to the right atrial appendage and Bachmann bundle to determine the atrial fibrillation threshold, defined as the minimal current required to induce rapid, irregular atrial electrical activity of at least 8 seconds' duration, Atrial fibrillation thresholds were determined at baseline (0.0% inhalational anesthetic), 0.5 minimal alveolar concentration (mac), and 1.0 mac of halothane (n = 8) and isoflurane (n = 8). In the absence of inhalation anesthetic, it was significantly (P < 0.01) easier to induce atrial fibrillation at the Bachmann bundle vs the right atrial appendage. Atrial fibrillation threshold at the Bachmann bundle was not affected by increasing concentrations of halothane, but was increased by 1.0 mac of isoflurane (P < 0.05). It was concluded that at 1.0 mac isoflurane, but not halothane, has antifibrillatory effects in atrial tissue.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.