Abstract

Recent investigations reveal that progressive collapse phenomenon is dominant behavior in the majority of steel structures. Although the design of buildings is based on the fact that they need to withstand all the loads exerted on the structure, failure occurs as a result of inadequate design and modeling techniques, particularly for abnormal and extreme loading conditions. Once one or more load bearing member is eliminated from the structure, progressive collapse, mainly in columns, will commence. By the time a column is eliminated from the structure as a result of a sudden motor vehicle strike or earthquake or fire or any other internal or external factor that could take one column out of the system, the weight of the building (gravity load) will be distributed among other columns within the structure. Failure commences in the part of the structure that has lost a column unless other columns are designed appropriately against gravity loads and are capable of redistribution of additional loads imposed on them. Failure of vertical load bearing elements will continue until the stabilization of extra loading. Hence, this could lead to serious damage and collapse of the building which will lead to higher damage to the building than the primary damage. This research is based on the regulations conforming to the specifications of UFC guidelines and the structures have been modeled using SAP2000 (2012). In order to study the effects of the progressive collapse on the seismic design of special steel moment frames, SMRF, two 5-story and 15-storystructures are modeled in SAP2000 (2012). In order to have a better understanding of progressive collapse and obtain reliable results, Linear Static (LS), Nonlinear Static (NLS) and Nonlinear Dynamic analyses (NLD) procedure for single and 2 adjacent columns removal have been implemented in this study. Having a good perception of the possibility of progressive collapse involves incorporation of demand capacity ratio, plastic hinges formation and vertical displacements of removed column’s location plus axial force in columns adjacent to the removed column. Other factors such as number of stories and the amount of local damage resulted from the removal of 2 adjacent columns could also lead to a better understanding of the structural behavior.

Highlights

  • After the 9/11 attacks and collapse of the World Trade Center towers in 2001, developers and governmental organizations have shown great interest in finding ways to evaluate the potential of progressive collapse of structures and design new structures to withstand this kind of threat

  • The progressive collapse potential of modeled structures incorporating linear static is demonstrated in Table 4, nonlinear static and nonlinear dynamic analyses

  • According to this research, discrepancies occurred in the assessment of progressive collapse potential for many cases according to the acceptance criteria mentioned in the guidelines including DCR for the Linear Static (LS) and ductility ratio and Connection Hinge rotation for the Nonlinear Dynamic (ND) and NL; it was observed that more conservative results was obtained using LS method compared to that of ND method

Read more

Summary

Introduction

After the 9/11 attacks and collapse of the World Trade Center towers in 2001, developers and governmental organizations have shown great interest in finding ways to evaluate the potential of progressive collapse of structures and design new structures to withstand this kind of threat. Updated guidelines for the purpose of evaluating the progressive collapse potential of structures have been published by the General Services Administration and Department of Defense (GSA, 2000; (UFC)-DoD, 2010). In order to localize the primary damage and avoid its spread to other parts of the structure, a series of direct and indirect design approaches are introduced by UFC documents. This study is based on the 2010 edition of the UFC 4-023-03 ((UFC)-DoD, 2010) which describes the design of structures subjected to potential terrorist attacks. Since in the majority of building design codes, the progressive collapse issue has been addressed implicitly, an attempt has been made in this study to understand whether the structures that have been designed for common load combinations under gravitational and seismic loading are prone to progressive collapse. Since in the majority of building design codes, the progressive collapse issue has been addressed implicitly, an attempt has been made in this study to understand whether the structures that have been designed for common load combinations under gravitational and seismic loading are prone to progressive collapse. Jinkoo and Taewan (2009)

Objectives
Methods
Findings
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.