Abstract

In the frame of an AREVA – KIT cooperation in the years 2008–2013 on R&D issues associated with Innovative sodium cooled fast reactor concepts, several major topics were identified as being of mutual interest to both partners, one of which was the evaluation of severe transient behavior in Sodium-cooled Fast Reactors (SFRs) and the impact of newly conceived mitigation measures. The SFR design taken for the analysis was the SFR(v2b-ST) reactor design, and the system code to be used was selected to be the SIM-SFR code. The transients chosen for evaluation of the efficiency of mitigation measures were the unprotected loss-of-flow (ULOF), the unprotected loss-of-heat-sink (ULOHS) and the unprotected transient-overpower (UTOP).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.