Abstract

The paper presents the methodology of calculations and technical justification for the use of new equipment. The section of the operating oil pipeline in the part of monitoring of heat engineering processes is considered. The main results of thermo-technical calculations of the pipeline section were described and the aureoles of thawing of the permafrost soil were simulated. As an example for replacement, a multilayer pipe with foamed polyurethane insulation and concrete casing was considered because of its better characteristics compared to the design one.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.