Abstract
Cerebral autoregulation is an important pathophysiological and prognostic parameter for a variety of neurologic conditions. It can be assessed quickly and safely using transcranial Doppler sonography (TCD). In elderly patients, poor insonation conditions decrease the number of examinable patients and can cause a systematic bias in autoregulation parameters. The aim of this study was to investigate whether a constant infusion of an ultrasound contrast agent (Levovist ®) can counteract these effects. We examined two cohorts of unselected neurologic patients. In 45 patients with good insonation windows (cohort 1), we used a thin aluminium foil between the skin and the TCD probe to artificially decrease the insonation quality. We determined two parameters of cerebral autoregulation (phase difference [PD] and a cross-correlation coefficient [Mx]) in native patients, with aluminium foil and with aluminium foil and a constant infusion of Levovist ®. In 30 patients with poor insonation windows (cohort 2), we measured the autoregulation twice, with and without an infusion of Levovist ®, to assess the reproducibility of the autoregulation parameters. In cohort 1, the foil model significantly decreased the Doppler signal quality, i.e., the mean spectrum energy decreased from 33.9 ± 2.7 dB to 26.3 ± 2.4 dB ( p < 0.001). This introduced a significant bias to all autoregulation parameters (PD: decreased from 38.2 ± 10.0° to 27.9 ± 12.5° ( p < 0.001); Mx: decreased from 0.308 ± 0.170 to 0.254 ± 0.162 ( p < 0.01)). Both effects were compensated largely by a constant infusion of Levovist ® (300 mg/min). In cohort 2, infusion of the contrast agent at the same rate increased insonation quality, too, but to a lesser degree (27.4 ± 2.4 dB to 32.0 ± 3.7 dB, p < 0.001). This smaller increase did not cause a significant change in the autoregulation parameters, but the reproducibility of the PD was significantly improved (intraclass coefficient coefficient [ICC] 0.76, 95% confidence interval [0.59–0.87] in native poor bone window compared with ICC 0.90, 95% confidence interval [0.81–0.95] with infusion of the contrast agent). Our data show that constant infusion of an ultrasound contrast agent during the assessment of cerebral autoregulation can avoid potential bias introduced by poor insonation conditions. Furthermore, infusion of the contrast agent can improve reproducibility and contribute to the credibility of autoregulation assessment in the elderly. (E-mail: matthias.lorenz@em.uni-frankfurt.de)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.