Abstract

This anatomical study was designed to assess the distribution of a solution (injectate) made up using local anesthetic, steroid and dye into the carpal tunnel using a commonly used injection technique. Dissections were undertaken in 29 embalmed cadaveric wrists. The cadaveric specimens were dissected 24 hours after injection to observe the effect of time on diffusion patterns in both superficial and deep planes. Eighteen of the 29 specimens showed the presence of the injectate in the superficial plane and three preferential patterns of distribution were noted in the deep plane: free in the carpal tunnel, exclusively in the tendon sheath and mixed. This is the first study investigating the delayed diffusion pattern of injectate in the carpal tunnel and illustrates its variability. The findings of variable degree of superficial diffusion and different patterns of intracarpal spread help to offer some explanation regarding the variability of the response following carpal tunnel injection.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.