Abstract

An efficient finite element approach was recently developed to analyse encased cold-formed steel (CFS) structures. This new technique replaced encasing material with unidirectional springs, analogous to the Winkler foundation concept, to shorten the analysis time while ensuring accuracy and reliability in predicting the structural behaviour of encased CFS components. In this paper, the validity, and limitations of the simplified spring model to represent outstanding plates were assessed. The investigation demonstrated that the simplified spring model could effectively predict the ultimate load for a wide range of ultra-lightweight concrete moduli (50-250 MPa) with an acceptable error. The analysis indicated that plate elements initially in cross-section class 4 without encasing material become at least class 3, or better as a consequence of encasing. Previously reported experiments were used to evaluate the performance of the ESM. The analysis demonstrated that the ESM can accurately predict the local failure ultimate load of encased CFS sections with an acceptable error percent and significantly less computational effort than a 3D solid model.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.