Abstract
A discussion is presented of the protection of the tokamak fusion reactor neutral-beam ion source, located at the Princeton Plasma Physics Laboratory. The system design is based on three operational protection requirements that include provisions for ion-source current pulse matching, ion-source fault current extinction, and metallic fault current extinction. A power circuit configuration satisfying these requirements is illustrated and briefly described. Simplified analytical expressions relating the protection requirements to the circuit parameters are developed. Experimental findings are in good agreement with a computer simulation of the circuit model, although several side effects introduced by the circuit configuration have been observed. The side effects observed include ion-source current overshoot and the existence of a negative ion source current. Modifications to counteract these side effects are briefly described. >
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.