Abstract

Spread spectrum clocking (SSC) has recently emerged as a very effective solution to mitigate electromagnetic interference (EMI) issues. In last years it has been widely used in switching dc/dc converters, in particular in class-D ones, i.e., that based on pulse-width modulation. Conversely, it finds no application in resonant ones. Within this paper we investigate the effects of applying SSC techniques to a recently introduced resonant class-E converter. Intensive SPICE simulations using both basic and advanced SSC techniques show not only that SSC is effective in mitigating EMI issues in this class of converters, but also that the most important circuit figures of merit such as conversion efficiency are not affected.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.