Abstract
Objective To explore the applicable conditions for using urine plutonium monitoring data to assess personal internal doses, in order to provide references for the occupational health management and the urine plutonium monitoring in nuclear sector. Methods Using some plutonium mixtures from DOE nuclear facilities, as an example, the urine plutonium levels were estimated through simulation calculation at 1 mSv effective dose arising from either acute or chronic inhalation of plutonium compounds, respectively. The results were compared with the typical detection limit of radiochemical separation and α-spectrometry. The feasibility of urine plutonium monitoring for dose assessment of internal radiation exposure was discussed. Results Only for type M plutonium compunds, 1 mSv detection limit can be achieved using radiochemical separation and α-spectrometry within 10 d after inhalation. Conclusions Before the monitoring plan of urine plutonium is made, detection limits of monitoring method should be considered. Internal dose could be accessed using workplace air monitoring and working hours when necessary. Key words: Plutonium mixtures; Urine plutonium monitoring; Internal expouse; Personal dose monitoring
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.