Abstract

The clinical usefulness of biodegradable oriented poly-L-lactide (PLLA) screws for experimental Salter-Harris type 4 fracture in the distal femoral condyle of dogs was evaluated. Bony union of the osteotomized fragment of the condyle was almost completed radiographically and histologically within 1 to 2 months after surgery, suggesting that PLLA screws maintained strength long enough to fix the fragment until bone healing. At 4 to 6 months after surgery, minute fissures were histologically confirmed on the surface of the screw thread, suggesting the early stage of biodegradation and absorption of the polymer. During the observational period, no significant difference between the treated femur and the contralateral non-treated femur in either total femoral length or maximum condyle width was observed, indicating no growth disturbance in the treated femur. From these results it was concluded that the PLLA screw might be an ideal implant for the reduction and fixation of epiphyseal plate fractures such as Salter-Harris type 3 or type 4 fractures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.