Abstract

This paper presents a systematic micro-analytical study for the assessment of the influence of a typical hot-air “blow-in” heating system on the generation, transport and deposition of suspended particulate matter (SPM) in the church of Rocca Pietore (Italian Alps). This kind of heating system is very popular in cold regions due to its fast response and economic properties. The size, chemical composition and abundance of individual particles responsible for the negative impact on the displayed artworks are determined by ultra-thin window EPMA. EDXRF is used to determine the bulk chemical composition of SPM. Some gaseous pollutants (SO2, NO2 and O3) are sampled with the application of passive diffusion tubes and quantified with ion-chromatography and spectrophotometry. It is pointed out that several deterioration processes, such as the abrasion of the plastered walls, the re-suspension of the particulate pollution and the generation of NO2 gas, arise mainly from using the heating system. Each of these observations is a concern for the preservation of the displayed works of art.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.