Abstract

In this paper, a new configuration is proposed for using Savonius rotors by installing two Counter-Rotating Savonius Rotors (CRSR) together. In order to study the aerodynamic performance of the CRSR turbine, 2D unsteady turbulent flow around the CRSR turbine is simulated using commercial CFD software ANSYS-Fluent16.0. Turbulence modeling is done using $$k - \omega$$ SST model. Numerical results demonstrate a considerable improvement in aerodynamic performance of the CRSR turbine in comparison to a single conventional rotor. Effect of the distance between two rotors and different angular positions of two rotors on the CRSR turbine performance is studied. It is shown that the most effective parameter influencing the performance of the CRSR turbine is the distance between the rotors. Numerical results reveal that, locating two rotors in an optimal phase angle (θ = 90) and distance(S = 1.0D0), average power coefficient of the CRSR turbine can be increased to 21%, which indicates a rise of 38% compared to conventional Savonius rotors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.