Abstract

Application of external skeletal fixation involves preoperative assessment of the fracture with regards to healing potential of the bone and stabilizing requirements of the fixator. The fixator can be used alone or with supplemental (IM pin, cerclage, hemicerclage, Kirschner wires, bone screws) fixation to counteract shear, bending, and torsional forces at the fracture site. In addition, cancellous bone grafting can be used to enhance fracture healing. Rigid frames should be based on predrilling pilot holes followed by slow speed or hand insertion of smooth and threaded pins. Precise knowledge of regional anatomy precludes iatrogenic neurovascular or muscular tissue damage, which, subsequently, improves patient morbidity. Postoperative care of the fixator consists of bulky wraps to control pin-skin motion and cleaning of pin tract drainage sites. "Dynamization" or bone loading can be performed during fracture healing to stimulate osteosynthesis. This involves staged disassembly and reduction of frames by removing pins and connecting rods.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.