Abstract

The determination of zinc in the presence of copper by potentiometric stripping analysis is hindered by the formation of Cu-Zn intermetallic compounds on the working electrode during the deposition step. An excess of gallium is usually added to the sample to prevent the formation of Cu-Zn by forming much more stable Cu-Ga intermetallics. If the Cu : Zn mass ratio is higher than about 5, only part of the analytical signal of zinc is restored after addition of gallium and both the precision and accuracy of the determination are reduced. A simple extraction procedure is recommended to remove the bulk of copper from the sample. The pH of the working sample solution is adjusted to 4 (0.5 M acetate buffer) and is extracted with half of its volume of a 3%V/V solution of acetylacetone in benzene. Each extraction removes about 80% of the copper present without affecting the zinc. The determination of zinc is subsequently carried out after adding HgII as an oxidant and gallium to mask the remaining copper. The method was applied to the determination of zinc in low-zinc, high-copper brass samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.