Abstract

1. Some methods of eliminating leakage current in strain gauges have been considered, which involve introducing an antishunting screen within the bonding agent. 2. Various styles of strain gauge with antishunting screens have been discussed, together with suitable circuits. A method has been suggested for calculating the error of a strain gauge with a screen, and formulas have been derived. An experimental test has been performed on the effect from an antishunting screen for a high-temperature platinum film strain gauge.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.