Abstract

ScopeSeveral methods are used worldwide for antibiotic susceptibility testing (AST) for the Mycobacterium tuberculosis complex (MTBC). The variability in the results obtained with these methods hampers setting epidemiological cut-off (ECOFF) values and clinical breakpoints according to EUCAST guidelines. Methods for susceptibility testing and determination of the minimal inhibitory concentrations (MICs) need to be standardized for MTBC isolates for old and new agents. Our objective was to establish a standardized reference method for MIC determination for MTBC. MethodsThe EUCAST antimycobacterial susceptibility testing subcommittee (AMST) compared protocols of MIC determination with regard to medium, inoculum preparation, antituberculous agent preparation, incubation, reading of the results and interpretation. RecommendationsThe EUCAST reference method of MIC determination for MTBC is the broth microdilution method in Middlebrook 7H9-10% OADC medium. The final inoculum is a 105 CFU/mL suspension, obtained from a 10−2 dilution of a 0.5 McFarland suspension prepared after vortexing bacterial colonies with glass beads before suspending them in sterile water. The culture is maintained in a U-shaped 96-well polystyrene microtitre sterile plate with a lid incubated at 36° ± 1°C. Reading is done using an inverted mirror as soon as the 1:100 diluted control (i.e. 103 CFU/mL suspension) shows visual growth. The MIC, expressed in mg/L, is the lowest concentration that inhibits visual growth. Mycobacterium tuberculosis H37Rv ATCC 27294 is used as the reference strain and its targeted MIC values are within the range 0.03–0.12 for isoniazid, 0.12–0.5 for levofloxacin and 0.25–1 mg/L for amikacin. ConclusionsThe EUCAST reference method for MTBC was endorsed by EUCAST after public consultation and will from now on be used to define EUCAST ECOFFs and clinical breakpoints. This reference method is not primarily intended to be used under routine conditions and the AST methods will need to be calibrated against this reference method to be used with EUCAST breakpoints.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.