Abstract

An association exists between water of poor quality and health care-associated infections. Copper shows microbiocidal action on dry surfaces; it is necessary to evaluate its antimicrobial effect against organisms in aqueous solution. The objective was to determine the in vitro antimicrobial activity of copper against common nosocomial pathogens in aqueous solution. Copper and polyvinyl chloride containers were used. Glass was used as control material. Fourteen organisms isolated from hospital-acquired infections, and 3 control strains were tested. Inocula were prepared by direct suspension of colonies in saline solution and water in each container tested. Bacterial counts in colony-forming units (CFU)/mL were determined at the beginning of the experiment; at 30 minutes; and at 1, 2, 24, and 48 hours. Organisms in glass and polyvinyl chloride remained viable until the end of the experiment. Organisms in copper showed a reduction from more than 100,000 CFU/mL to 0 CFU/mL within the first 2 hours of contact (F > 4.29, P < .001). Copper containers show microbiocidal action on organisms in aqueous solution. Copper may contribute to the quality of water for human use, particularly in hospitals.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.