AbstractThe diffusion of implanted chlorine in silicon wafers is studied with neutron activation/accelerator mass spectroscopy (NA/AMS). Depth profiles are obtained from as-implanted and annealed samples. While there is a marked difference between the annealed and as-implanted profiles for the lowest implant dose studied, 1013/cm2, the chlorine from the higher dose implants is virtually immobile. The diffusion of implanted chlorine in silicon is characterized by the apparent absence of indiffusion for the experimental conditions studied. However, outdiffusion is rapid at low concentrations for anneal temperatures of 1100°C and above. This behavior is qualitatively similar to that reported for fluorine in silicon at lower temperatures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.