Abstract

Eighteen dogs were randomly chosen to undergo mitral annuloplasty with either a Carpentier-Edwards rigid ring (n = 6 in each group) or a Duran-Medtronic flexible ring or to undergo a sham procedure with an operation, but no ring. Tantalum markers were inserted to measure left ventricular volume and geometry. After 1 and 6 weeks, biplane videofluoroscopic images were obtained during steady-state conditions and during vena caval occlusion. Global and regional systolic function was assessed with load-insensitive indexes. Comparison of all three groups and both times (1 and 6 weeks) showed no significant differences among the three groups in global or regional (basal, equatorial, and apical) left ventricular systolic performance. Furthermore, neither type of annuloplasty ring significantly affected left ventricular pump efficiency, ventricular-arterial coupling ratio, or systolic circumferential contraction and rotation of the basal left ventricular sites.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.