Abstract

Rayleigh waves have been used to measure anisotropy in metal alloys using a transient Rayleigh pulse and an eight-element electromagnetic acoustic transducer array. The array spacing determined sensor separation, so that velocity measurements were made independent of the source-to-detector distance. Elimination of this distance, which would normally lead to systematic errors, has resulted in a measurement system capable of measuring velocities in metal to an uncertainty of 0.1%. As an example, variations in the Rayleigh velocity have characterized the anisotropy in rolled bars of aluminum.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.