Abstract
The Escalator steps are one of the most important parts of escalators. The step is a special structure of the four-wheel car, there are two main wheel and two auxiliary wheel. In this paper, by taking a variety of analytical methods, such as visual inspection, chemical composition analysis, and microstructure, analysis on the cause of step fracture in the escalator step arch event. According to analysis, we can conclude that the escalator step collision event is not caused by the step body. Due to improper adjustment of escalator ladder, causing the step pedal to align with the upper comb plate, eventually triggering a step collision event.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: DEStech Transactions on Materials Science and Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.