Abstract

This study aims to reduce running time of ice-warm-hot drinking system in heating and refrigerating for the purpose of saving energy. In the experiment warm water heat exchanger and preheater are used to perform primary and secondary preheating of raw water and cooling the water fed into the ice water bucket to reduce running time of heater and refrigerating system. The experiment result shows that the system equipped with heat recovery device can reduce times of heating and refrigerating under heat preservation mode for 24 hours; under differential operation conditions, the system equipped with warm water heat exchanger and preheater saves energy by 7.9%-35.2%. The heat recovery device installed by this study indeed reduces electricity consumption of the system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.