Abstract

The experimental results for two regimes of mixing of a passive impurity in an axisymmetric jet mixer — the mixing of a turbulent jet and a cocurrent flow to form a recirculation zone behind the nozzle and an analogous mixing without the formation of a recirculation zone (Red = 10,000) — have been presented. The velocity field has been measured in the mixer cross sections at different distances from the nozzle (0.1 < x/D < 9.1) with a one-component Doppler laser anemometer, whereas the scalar field (concentration of the passive impurity) has been diagnosed by the laser-induced fluorescence method. Based on the scalar distributions obtained, the autocorrelation function and the integral scale have been computed, the form of the probability density function has been restored, and the distributions of the asymmetry and excess coefficients have been constructed. Visualization of flow in the mixer has been carried out.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.