Abstract

ABSTRACT The effect of variation in open area ratio (β) in multi-V rib roughened single pass solar air heater (SPSAH) is computed in this study. Different perforated plastic ribs are used to develop variations in perforation. Four values of the open area ratio (β) ranged from 0 to 0.31, six values of relative roughness width (W/w) ranged from 2 to 10, and nine values of the Reynolds number (Re) ranged from 2000 to 18,000. These values were under consideration, along with fixed values of other parameters. Optimum values of performance parameters achieved at an open area ratio β = 0.27 with W/w = 6. The optimum range of improvement in Nusselt number ratio (Nu/Nus) and thermo-hydraulic performance parameter (THPP) was 6.33–8.19 and 3.78–5.41, while duct friction ratio (f/fs) was recorded within the range of 3.68–4.78 when compared to the flat channel, respectively. A correlation for Nusselt number and friction factor with varying parameters was also established with ±12% and ±7.5% accuracy, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.