Abstract

During loss-of-coolant accidents (LOCAs), operators may start accident management (AM) actions when the core exit temperature (CET) measured by thermocouples exceeds a certain value. However, a significant time delay and temperature discrepancy in the superheat detection were observed in several facilities. This work is focused on clarifying CET thermocouple responses versus peak cladding temperature (PCT) and studying if the same physical phenomena are reproduced in two TRACE5 models with different geometry (a large-scale test facility (LSTF) and a scaled-up LSTF) during a pressure vessel (PV) upper head small break LOCA (SBLOCA). Results obtained show that the delay between the core uncover and the CET excursion is reproduced in both cases.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.