Abstract Based on the finite element method, Finite cell model of the stray current transmission net was established, and the mathematical expression of track potential, track current and stray current was proposed in the DC traction power system. And the analysis model of track to earth insulation defect was built. Simulated and analyzed the stray current distribution under track to earth insulation well and defect. Analysis shows that stray current is almost leaked out the point after insulation defect occur, and the total amount of stray current and the maximum value of track to earth potential will be increased. current and potential are effected by insulation defect.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.