Abstract

Retrofitting materials like aluminum bars, steel overlays and glass fiber mixes has been utilized in the development field for a long time. Carbon fiber mixes are the ongoing expansion to the retrofitting materials. Trial and expository investigation have been done and compared.Total number of 6 shafts yet of which 3 are control bars and the other 3 pillars pre harmed 70%of extreme burden and after that enveloped by the base with CFRP laminates.Experimental examination completed by applying two-point load. Investigative examination by FEM specifically utilizing ABAQUS the predications utilizing the proposed diagnostic model are in great concurrence with the exploratory outcomes

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.