Abstract

Potential induced degradation (PID) of photovoltaic (PV) modules is one of the frequently observed failures in PV installations nowadays. This study investigates the inhomogeneous and complex PID generation on rooftop installations on industrial buildings as well as its impact on the module performance. The PID development is exemplarily presented for a 314kWp PV-plant installed in the Atlantic coastal climate. Due to the complex plant geometry and resulting irradiation situation the existence of PID could not be identified based on the annual yield data. By Infrared imaging PID was clearly identified. Evaluating historic monitoring data, the impact of PID on the string and plant performance could be quantified. A linear correlation between the defect ratio and the performance rate as well as the degradation loss rate could be formulated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.