Abstract
High pressure liquid chromatography (HPLC) using an electrochemical (EC) detector electrode of pyrolytic graphite coated with a film of ionomer Nafion and the water-insoluble surfactant didodecyldimethylammonium bromide (DDAB) was used to achieve separation and detection of all six bromo- and chloro-acetic acids. The Nafion-DDAB film preconcentrates the acid anions facilitating their electrochemical detection by direct reduction at −1.2 V versus SCE. Detection limits were poorer than the EPA-approved GC-ECD method, but HPLC-EC avoids the derivatization necessary for GC. The HPLC-EC method also detected tribromoacetic acid, which has not been determined simultaneously with other halogenated acids by reported chromatographic methods. The HPLC-EC method using a Nafion-DDAB-coated detector electrode gave comparable results to GC-ECD for the determination of TCA in drinking water.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.