Abstract
A series of normal aliphatic thiols have been used to derivatise the chemical warfare agents Lewisites I and II (LI and LII) in hydrocarbon matrices. Varying the chain length of the thiol allowed adjustment of derivative t R by 5.9 min for Lewisite I and 5.3 min for Lewisite II. Linear regression analysis of the chain length of the thiol derivatives of the Lewisite species, and that of a series of normal alkanes against t R, allowed regression models to be developed for each set of compounds. Application of the models allowed thiol reagents to be chosen to give derivatives of Lewisites I and II that eluted before and after the major hydrocarbon contaminant. Limits of detection were comparable for all thiol derivatives analysed by GC–MS in the selection ion monitoring mode (all below 1 μg ml −1). The robustness of this approach was illustrated by successful identification of Lewisite I in samples from the Sixth Proficiency Test (organised by the Organisation for the Prohibition of Chemical Weapons, OPCW) in a matrix of 1 mg ml −1 diesel oil.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.