Abstract
This paper presents a single-phase transformerless bidirectional power factor corrector (PFC). A capacitor is inserted into a conventional full-bridge PFC by connecting the ac line terminal and a terminal of DC voltage. The functions of this inserted capacitor have two roles: to bypass the common-mode leakage current from the stray capacitor; to form an LCL filter to reduce the inductor current ripple. A hybrid modulation method is employed in this PFC. The unipolar switching scheme is applied to modulate the PFC, which can achieve high efficiency. Meanwhile, an additional modulation is inserted into the blank time of low-frequency switches to decrease the changing speed of the voltage on the inserted capacitor, and to decrease the spike on the inductor current and leakage current. The performance of the PFC is experimentally verified using a 5 kW prototype.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.