Abstract

An electrical overstress (EOS) short failure was observed on ball grid array (BGA) package during the temperature humidity bias (THB) stress test. The cause of the EOS short failure has been identified to be attributed to 3 factors, i.e. the VDD/VSS copper lines of the BGA substrate which have been laid out closely at the same side of the substrate, the solder resist crack and the high humidity nature of the THB stress test. To resolve this problem, the BGA substrate layout has been redesigned so that the close pairs of the VDD/VSS copper lines are separated into two opposite sides of substrate. No EOS short failure was observed on the BGA package with new substrate design after the THB stress test.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.