Abstract

This study introduces a cost-effective, automated ultra-high-performance liquid chromatography-tandem mass spectrometry method for the detection of 14 β-agonists in pork using a novel solid-phase microextraction probe composed of polyacrylonitrile and molecularly imprinted polymer. Integrated into an automated extraction device, the probe optimizes extraction prior to analysis while reducing expenses and time compared to traditional solid-phase extraction procedures. The method validation followed the Chinese National Standard (GB/T 27404-2008) and examined limits of detection, limits of quantification, matrix effects, linearity, intraday, and interday precision. Average recovery rates ranged from 71.6% to 82.2%, with relative standard deviations less than 15%. Limits of detection and limits of quantification ranged from 0.09 to 0.39 and 0.27 to 0.99μg/kg, respectively. The new method identified positive samples more accurately than the current National Standard GB/T 31658.22-2022 and demonstrated its potential for routine assessment and regulatory compliance in the detection of β-agonists in pork.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.