Abstract
Microelectromechanical system (MEMS) relays are gradually replacing traditional relays because they are smaller and lighter and consume less power. However, performance parameters of MEMS relays, such as the pull-down voltage, response time, and resonant frequency, often deviate from those originally designed, due to residual stress generated during the fabrication process. We present herein a method to measure this residual stress, based on a metal bridge membrane MEMS relay, with the help of a nanoindenter and the finite-element method (FEM). The testing result lies in a reasonable range, indicating that this simple method is reliable and helpful for MEMS relay optimization.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.