Abstract

ObjectiveTo describe the rate of occurrence of unsuspected decrease in sensitivity of the sound processor microphone and to evaluate its effect on the patient's audiological performance in terms of reduction in speech recognition scores.DesignSpeech processor microphones were tested by connecting the speech processor acoustic monitor circuit to a hearing aid analyzer. The response curves were compared with those obtained from fully working microphones.During a 6-month investigation period, microphone response curves were measured from a group of cochlear implant recipients who had not reported any problems. Despite the absence of any subjective problem, some microphones were found to show a loss of sensitivity. Their users, aged between 4 and 67 years, were tested both with the defective and a working microphone in order to calculate the correlation between the degree of microphone failure and the decline in audiological performance.To quantify the effect of microphone failure, patients’ speech recognition skills were measured by live voice connected discourse tracking series administered in different conditions and by recorded sentences lists.ResultsA total of 120 apparently fully functioning sound processors were tested in the investigation: 33 (27.5%) were affected by a subjectively unreported sensitivity decrease. Speech-tracking scores correlated significantly with the loss of microphone sensitivity in all test conditions (r = 0.69–0.77, P < 0.05). A high degree of correlation was also found for speech audiometry tests (r = 0.70–0.73, P < 0.05). Microphone sensitivity loss affected speech recognition skills, especially without lip reading and in the presence of background noise.ConclusionThe results indicate that any reduction in sound processor microphone sensitivity causes a degree of hearing decline that negatively affects the cochlear recipient's clinical performance. Microphone faults are often unreported events, and their occurrence rate is underestimated. To establish that the microphone is providing correct input to the speech processor a standard control procedure, including technical and clinical checks, is needed in clinical practice.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.