Abstract

The work describes an isotope generator of polonium-210 based on an extraction chromatographic resin SR Resin. It was shown that a high selectivity of 4,4’(5’)-di-t-butylcyclohexano-18-crown-6, an active component of SR Resin, for lead allows a clear separation of Pb-210 from impurities, easy elution of Po-210 with 5–7 mL of 0.05 M nitric acid solution as well as good retention of Pb-210 in the generator. The content of alpha emitting impurities in the Po-210 eluate did not exceed 0.65%. The experience of 3-years exploitation of the generator is described. It was shown that the SR Resin was stable against irradiation and complete drying, and Pb-210 loss from the SR Resin column for 3 years (seven elutions) was near to loss due to its radioactive decay within the error limits (less than 7%).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.