Abstract

The results of an experimental investigation of the average liquid film thickness are presented for vertical upward annular-mist two-phase flow, with and without heat transfer. The effects on the film thickness for variations in vapor flow rate, liquid flow rate, vapor density, and heat transfer are described. A correlation equation is presented for the local time-averaged thickness and for the droplet size distribution. In addition, an equation is given for the liquid film flow rate as a function of the average film thickness.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.