Abstract

The prediction capability of the 1995 CHF look-up table (Groeneveld D.C., et al., Nucl. Eng. Des. 163 (1996) 1–23) is independently assessed based on the KAIST data base consisting of 10 822 data for uniformly-heated, vertical, round tubes. This confirms the error statistics for the heat balance method reported by Groeneveld et al. and shows overall average and RMS errors of 4.2 and 36.7%, respectively, for the direct substitution method. The new 1995 table shows better prediction capability than the 1986 AECL-UO table ( Groeneveld et al., 1986), especially for the low-pressure, low-flow region. The error analysis indicates the length effect even for significantly long tubes.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.